EMERGENCY DIESEL GENERATORS

DIESEL GENERATOR MODEL WM5000CLE

DIESEL GENERATOR OPEN FRAME

Model WM5000CLE
Engine type Single Cylinder, four stroke, air cooled, direct injection diesel engine
Phase Single phase or Three phase
Rated freq.(Hz) 50 Hz
Rated power(Kw) 5.0 Kw at 3600 rpm (6.5 KVA)
Rated voltage(V) 230 Volt
Rated current(A) 22 Amp
DC output(V/A) 12V / 8.3A
Starting system Electric start and Recoil start
Fuel capacity 15 L
Dimensions 920x615x760 mm
Maximum continuous running time is 6.5 Hours
DIESEL GENERATOR MODEL WM5000CL-1

DIESEL GENERATOR CLOSED FRAME

Model WM5000CL-1
Engine type Single Cylinder, four stroke, air cooled, direct injection diesel engine
Phase Single phase or Three phase
Rated freq.(Hz) 50 Hz
Rated power(kw) 5.0 Kw at 3600 rpm (6.5KVA)
Rated voltage(V) 230 Volt
Rated current(A) 22 Amp
DC output(V/A) 12V / 8.3A
Starting system Electric start
Fuel capacity 15 L
Dimensions 920x615x760 mm
Maximum continuous running time is 7.5 Hours
DIESEL GENERATOR MODEL WM12000CLE

DIESEL GENERATOR MODEL WM12000CLE

Model WM12000CE
Engine type Single Cylinder, four stroke, air cooled, direct injection diesel engine
Phase Single phase or Three phase
Rated freq.(Hz) 50 Hz
Rated power(Kw) 10 Kw at 3000 rpm (Max 12 KVA at 3600 rpm)
Rated voltage(V) 230 Volt
Rated current(A) 52 Amp
DC output(V/A) 12V / 8.3A
Starting system Electric start
Fuel capacity 26 L
Dimensions 1030x825x735 mm
Maximum continuous running time is 7.5 Hours
diesel-generator-hp4000cx-e

DIESEL GENERATOR MODEL HP4000CX(E)

Model HP4000CX(E)
Engine type Single-cylinder, 4-stroke, Vertical, air-cooled, Diesel engine
Phase Single phase
Rated freq .(Hz) 50 Hz
Rated power (Kw) 2.8 Kw
Rated voltage (V) 230 Volt
Rated current (A) 13 Amp
DC output 12V
Starting system Manual or Electric Start
Fuel capacity 12.5 L
Dimension L×W×H(mm) 680x460x560 mm
Maximum continuous running time is 9 Hours
DIESEL GENERATOR SILENT TYPE HP6700LN

DIESEL GENERATOR / SILENT TYPE HP6700LN

Model HP6700LN
Engine type Single-cylinder, 4-stroke, vertical, air-cooled, diesel engine
Phase Single phase
Rated freq.(Hz) 50 Hz
Rated power(Kw) 4.6 Kw
Rated voltage(V) 230 Volt
Rated current(A) 20 Amp
DC output 12V
Starting system Electric start
Fuel capacity 14.5 L
Dimension L×W×H(mm) 910×520×740 mm
Maximum continuous running time is 6.5 Hours
diesel-generator-HP7500LN

DIESEL GENERATOR MODEL HP7000LN

Model HP7000LN
Engine type Single-cylinder, 4-stroke, Vertical, air-cooled, Diesel engine
Phase Single phase
Rated freq .(Hz) 50 Hz
Rated power (Kw) 6.5 Kw [8 Kva]
Rated voltage (V) 230 Volt
Rated current (A) 27 Amp
DC output 12V
Starting system Electric Start
Fuel capacity 24L
Dimension L×W×H(mm) 910×520×840 mm
Maximum continuous running time is 7.5 Hours
diesel-generator-hp13000

DIESEL GENERATOR MODEL HP1300LN

Model HP1300LN
Engine type Twin-cylinder, 4-stroke, Vertical, air-cooled, Diesel engine
Phase Single phase
Rated freq .(Hz) 50 Hz
Rated power (Kw) 10 Kw [13 Kva]
Rated voltage (V) 230 Volt
Rated current (A) 50 Amp
DC output 12V
Starting system Electric Start
Fuel capacity 32L
Dimension L×W×H(mm) 1260x660x760 mm
Maximum continuous running time is 8 Hours
GENERATOR AUTO TRANSFER SWITCH ATS CONTROLLER MODULE

GENERATOR AUTO TRANSFER SWITCH ATS CONTROLLER MODULE

Model ATS0201T
Description Automatic switch which will automatically start generator and continue to supply power to your house or workshop, when the grid supply re-starts the ATS unit will automatically switch off generator and switch house or workshop etc back over to grid supply.
Voltage 240VAC 50Hz
Output Current MAX 30A
Control Cable Included
Weight 1.5kg
Dimension L×W×H(mm) 180x103x86 mm
  

The safe use of generator equipment:

End-users who use portable generators to interface with fixed electrical installations must adhere to the regulations of the OHS Act and SANS 10142-1.

Many end-users cause illegal electrical installations when they resort to alternative power supplies during utility outages. SANS 10142-1 clause 7:12 prescribes the minimum safety requirements for the use of alternative power sources. This standard makes it very clear that alternative supplies include but are not limited to LV generating sets and photovoltaic (PV) installations.

The requirements are of a very technical nature and must be clearly understood and applied. All electrical installations must also comply with the Electrical Installation Regulations. Failure to comply with the regulations and standards may lead to prosecution or invalidate insurance claims and warantees.

Note: Remember that a generator installation must be executed by a person registered with the DoL. The registered person must issue a CoC upon completion of the electrical installation. Warranties on generators will be null and void if not installed by a qualified electrician and no CoC. (Certificate of Compliance)

Safe work practices

General requirements
SANS 10142-1:2012

7.12.2 Requirements for alternative sources of supply
7.12.2.1 Where any form of alternative supply (emergency supply, UPS etc.), is connected to an electrical installation, a notice to this effect shall be displayed at the main switch of the installation, and where such supply
a) supplies power only to certain circuits in a distribution board, a power-on indicator (visible or audible) shall be provided on each such distribution board as well as a notice indicating that the standby power main switch shall also be switched off in an emergency,
b) only supplies a part of the electrical installation, the notice shall also be displayed on each distribution board in that part of the installation (see 6.6.1.1(d)).
7.12.2.2 The means of excitation and commutation shall be appropriate for the intended use of the generating set and the safety and proper functioning of other sources of supply shall not be impaired by the generating plant.
7.12.2.3 The prospective short-circuit current and prospective earth fault current shall be assessed for each source of supply or combination of sources, which can operate independently of other sources or combinations. The short-circuit rating of protective devices within the installation and, where appropriate, connected to the main supply, shall not be exceeded for any of the intended methods of operation of the sources.
7.12.2.4 Where the alternative supply is intended to provide a supply to an installation that is not connected to the main supply, or to provide a supply as a switched alternative to the main supply, the capacity and operating characteristics of the alternative supply shall be such that danger or damage to equipment does not arise after the connection or disconnection of any intended load as a result of the deviation of the voltage or frequency from the standard range. Means shall be provided to automatically disconnect such parts of the installation, as may be necessary if the capacity of the alternative supply is exceeded.
7.12.2.5 Where an alternative supply is provided to an installation or part of an installation as a switched alternative to the main supply, the change-over switching device shall disconnect the main supply before the alternative supply is switched in. The change-over switching device shall be interlocked in such a way that the main supply and the alternative supply cannot be connected to the installation or part of the installation at the same time.
7.12.2.6 Except where otherwise permitted in this part of SANS 10142, where a socket-outlet is installed in a circuit on standby power, such circuit shall be protected by an earth leakage protection device with a rated earth leakage tripping current (rated residual current) I∆n not exceeding 30 mA.
7.12.2.7 A 230 V generator with a V-O-V earth connection (centre tap on winding which is earthed), shall not be connected to a fixed electrical installation.
Note: Such a generator may be used as a free-standing unit to provide power to specific appliances.